- Date
- 30 January 2014
- Registration
- VT-ANE / VT-TLE
- Aircraft
- B 787-8
- Operator
- Air India
- Location
- Mumbai (VABB)
- Report
- Final report
- Investigated by
- AAIB India (Indian body)
VT-ANE / VT-TLE · Serious incident: air proximity at Mumbai
AAIB India report title: Serious Incident of air proximity between aircraft VT-ANE and aircraft VT-TLE at Mumbai on 30.01.2014
Probable cause · AAIB India
The Controller giving routing to aircraft VT-TLE direct to DOGAP which was cutting across the take-off path of the aircraft VT-ANE (AIC116D), took the aircraft VT-TLE into conflict with aircraft VT-ANE and subsequently resulted into the incident.
What happened
On 30th January 2014 the Sesa Goa P68C aircraft VT-TLE, under the command of a pilot CPL holder on type took-off from Runway 26 of Juhu Aerodrome at 0429 UTC for Pune. Another B787 aircraft VT-ANE of Air India took off from runway 14 CSIA (Mumbai) Aerodrome for Delhi under the command of a pilot an ATPL holder on type with co-pilot also an ATPL holder on type and 236 passengers including 10 cabin crew on board. The aircraft VT-TLE after take-off from runway 26 of Juhu aerodrome came in contact with Mumbai Approach Control on 127.9 MHz. The aircraft was given climb to 3000ft and was asked to proceed direct to DOGAP, which was cutting across the take-off path of Runway 14 (runway in use) of CSIA (Mumbai) Aerodrome at approximately 4.5NM from Runway14. The aircraft VT- ANE, after take-off from Runway14 of Mumbai came in contact with Mumbai Approach Control passing 2100 ft at 0435UTC. At that time, VT-TLE was almost crossing the take-off path of Runway14 Mumbai Aerodrome at approx. 4.5NM from Runway14. This prompted the approach controller to expeditiously climb VT-TLE to FL70. Later at time 043620 UTC the approach controller gave VT-ANE a left heading of 360 which was later amended to left heading 340 to avoid traffic. At time 043640 the approach controller restricted VT-TLE to maintain 4000ft and turn left heading 180 and asked VT-ANE to climb to FL140 and expedite passing FL80.
Findings
- 1. Runway in use at Mumbai Aerodrome was 14 for arrivals and departures. Traffic in Mumbai Approach was moderate. However, the controller had been manning the channel for last one and half hour.
- 2. VT-TLE departed from Runway 26 from Juhu Aerodrome at time 0429UTC.
- 3. VT-TLE was a VFR traffic and was not identified on RADAR.
- 4. VT-TLE was given direct to DOGAP after the aircraft came in contact with the Approach Controller.
- 5. After giving the aircraft direct DOGAP, VT-TLE heading was intersecting the take-off path of Runway 14 at approximately 4.5NM from the Runway 14 end.
- 6. The Approach controller did not restrict/ delay departure from Runway 14 even after giving VT-TLE direct to DOGAP which was taking her to the takeoff path of Runway 14.
- 7. When SVA745 contacted APP RADAR after departing RUNWAY14 Mumbai Aerodrome, RADAR passed VT-TLE traffic information of SVA745 which was climbing 5NM ahead of VT- TLE (non-standard phraseology used) and asked VT-TLE to maintain 3000ft on reaching. Thereafter, the controller was engaged in handling other traffic, and failed to recognise and resolve the situation developing at VT-TLE continued on…
- 8. When AIC116D after departure from Mumbai RUNWAY14 & came in contact with APP RADAR, then he asked VT-TLE to climb FL70 and expedite. However, the two aircraft performance characteristics were different. VT-TLE was an aircraft of a lower speed with slower climb rate whereas B787 is a far higher speed aircraft with a faster rate of climb. This exacerbated the situation more.
- 9. Further, at this time AIC116D was also climbing FL70 (as per SID) and it also readback this twice. At this moment both aircrafts were climbing to FL70. Vertical separation was attempted by the RADAR controller. In fact, 20 secs before AIC116D received RA, RADAR asked VT-TLE to stop climb at 4000ft and recleared AIC116D to FL140 and expedite climb to FL80 and passed it traffic information of…
- 10. The first avoidance headings were issued by RADAR controller to AIC116D 60 seconds after, & to VT-TLE 70 seconds after, AIC116D first made contact with RADAR Controller. This was just 30 seconds before AIC116D received RA.
- 11. AIC116D reported TCAS RA at 4000ft approximately 6NM from Mumbai. It was observed maneuvering and descending for RA.
- 12. The controller gave AIC116D instructions, after AIC116D had reported receiving RA but had not reported ‘CLEAR OF TRAFFIC’.
Safety recommendations
- 1. AAI to develop or review Standard Operating Procedures (SOPs) for handling of fixed wing VFR movement from Juhu.
- 2. AAI may impart suitable corrective training to the Approach Controller for use of standard phraseology and handling VFR traffic from Juhu and for actions required, if an aircraft reports RA.
- 3. AAI shall re-emphasis on handling of VFR traffic from Juhu Aerodrome for all approach controllers during their refresher training program,
Source reports
- Serious Incident of air proximity between aircraft VT-ANE and aircraft VT-TLE at Mumbai on 30.01.2014 (Final report)
Questions
What happened to VT-ANE / VT-TLE on 30 January 2014?
On 30th January 2014 the Sesa Goa P68C aircraft VT-TLE, under the command of a pilot CPL holder on type took-off from Runway 26 of Juhu Aerodrome at 0429 UTC for Pune. Another B787 aircraft VT-ANE of Air India took off from runway 14 CSIA (Mumbai) Aerodrome for Delhi under the command of a pilot an ATPL holder on type with co-pilot also an ATPL holder on type and 236 passengers including 10 cabin crew on board. The aircraft VT-TLE after take-off from runway 26 of Juhu aerodrome came in contact with Mumbai Approach Control on 127.9 MHz. The aircraft was given climb to 3000ft and was asked to proceed direct to DOGAP, which was cutting across the take-off path of Runway 14 (runway in use) of…
What caused the serious incident involving VT-ANE / VT-TLE?
According to the AAIB India report: The Controller giving routing to aircraft VT-TLE direct to DOGAP which was cutting across the take-off path of the aircraft VT-ANE (AIC116D), took the aircraft VT-TLE into conflict with aircraft VT-ANE and subsequently resulted into the incident.
Who investigated the serious incident involving VT-ANE / VT-TLE?
The Aircraft Accident Investigation Bureau (AAIB), India. The final report was signed 868 days after the occurrence, on 16 June 2016. Latest report: final report.
What safety recommendations were made after the serious incident involving VT-ANE / VT-TLE?
The report makes 3 safety recommendations. 1. AAI to develop or review Standard Operating Procedures (SOPs) for handling of fixed wing VFR movement from Juhu. 2. AAI may impart suitable corrective training to the Approach Controller for use of standard phraseology and handling VFR traffic from Juhu and for actions required, if an aircraft reports RA. 3. AAI shall re-emphasis on handling of VFR traffic from Juhu Aerodrome for all approach controllers during their refresher training program,
Full case page: events, crew, weather, defence layers and page links
Related cases
- Air India Boeing 787-8 VT-ANE · Serious incident at Hong Kong
- PH-BHG / VT-IFO · Serious incident: air proximity at Delhi
- VT-AND / VT-ANI · Serious incident: air proximity at Delhi
- Thai Airways B787-9 G-ZBKF · Serious incident: air proximity at Delhi
- G-VBZZ / VT-ANM · Serious incident: airprox at Mumbai Oceanic Region
- ET-ATL / VT-TQL · Serious incident: airprox