Alliance Air ATR-72-212A VT-AIW · Serious incident: hard landing at Jabalpur
AAIB India report title: Serious Incident to aircraft VT-AIW at Jabalpur on 12.03.2022
Probable cause · AAIB India
The probable cause of the Serious Incident was
What happened
On 12 Mar 2022, Flight 9I-9617 was scheduled to operate from Delhi to Jabalpur. The flight was operated by ATR-72-212A (600) aircraft bearing registration VT-AIW. The flight was operated by an ATPL holder PIC and a CPL holder Co-Pilot and they were assisted in the cabin by 02 cabin crew. There were 55 passengers on board the aircraft. During landing at Jabalpur, the aircraft crossed the threshold at a height of about 60 feet and floated for approximately 19 seconds before making a late touchdown more than half way down the runway and bounced before touchdown again at about 1600 m from beginning of the Runway 24. The aircraft was left with only about 400 m of runway for braking. The aircraft continued to roll and started to deviate to the left of runway centerline as it exited the runway and entered RESA. The aircraft rolled further in the RESA and came to halt about 60 m ahead of runway end and about 45 m left of runway center line. Airport Rescue and Fire Fighting vehicles also arrived at the site. As no fire or fuel leakage was found, no fire extinguishing agent or media was used. All passengers safely deplaned and were transported to the arrival area. The occurrence was classified as a Serious Incident as per Aircraft (Investigation of Accidents and Incidents) Rules, 2017. With approval of Ministry of Civil Aviation, Sh Jasbir Singh Larhga, Deputy Director, AAIB was appointe
Findings
- 1) The Certificate of Airworthiness, Certificate of Registration and Airworthiness Review Certificate of the aircraft were valid on the date of incident and the aircraft was airworthy.
- 2) Flight crew were medically fit and their licences were current to operate the flight. Both crew met the requirements for operating flight to Jabalpur which was a Category B aerodrome.
- 3) Airline was not monitoring Long Flare as required by the DGCA approved Flight Safety Manual till end of February 2022.
- 4) Six instances of Long Flare in 04 days prior to incident flight were observed from the data provided by the airline. It is possible that many such instances were never monitored by the airline prior to February 2022 due software limitations.
- 5) No corrective training or feedback was provided to the PIC by the airline with respect to Long Flare or other exceedance which were not flagged in the FDAP.
- 6) Flight experienced 05 Kt headwinds during approach which changed to 05 kt tailwinds before touchdown and 05 kt cross winds during touchdown, however the winds were within operational limitations of the aircraft.
- 7) Runway 24 has a slope of -0.77% as per the published AIP, which was within the operational limitations of the aircraft.
- 8) The approach was not stabilized as average IAS during approach remained 17 kt above the target IAS which was 107 kt. The peak value reached was 134 kt which was significantly above the target IAS.
- 9) The airline’s FDA software indicated a Long Flare of about 19 seconds.
- 10) Aircraft mostly remained in a negative pitch attitude during flare and both touch downs.
- 11) There was lack of call-outs by PM for deviation in flight parameters during approach.
- 12) Crew did not consider “Go-Around” and continued with landing while remaining runway length was insufficient to stop. No call for “Go-Around” was monitored in the CVR recording.
Safety recommendations
- 4.1 Airline should carry out complete monitoring of Flight Data for all parameters defined in the Flight Safety Manual and provide feedback and corrective training to its crew based on trends monitored in FDAP in a timely manner.
- 4.2 Airline may review its FDM parameters to see the feasibility of including inappropriate flare and delayed retardation of power levers to Flight Idle as a parameter to be monitored in the FDM.
- 4.3 Airline should re-iterate to its pilots the importance of adherence to stabilized approach criteria.
- 4.4 Airline should re-iterate to its pilots the importance of proper briefings and callouts for any deviations from the flight path.
- 4.5 DGCA should issue instructions to all airline to encourage their pilots to exercise option of rapid deplaning in emergency situations or incidents when full scale evacuation may not be required.
Source reports
Questions
What happened to VT-AIW on 12 March 2022?
On 12 Mar 2022, Flight 9I-9617 was scheduled to operate from Delhi to Jabalpur. The flight was operated by ATR-72-212A (600) aircraft bearing registration VT-AIW. The flight was operated by an ATPL holder PIC and a CPL holder Co-Pilot and they were assisted in the cabin by 02 cabin crew. There were 55 passengers on board the aircraft. During landing at Jabalpur, the aircraft crossed the threshold at a height of about 60 feet and floated for approximately 19 seconds before making a late touchdown more than half way down the runway and bounced before touchdown again at about 1600 m from beginning of the Runway 24. The aircraft was left with only about 400 m of runway for braking. The aircraft…
What caused the serious incident involving VT-AIW?
According to the AAIB India report: The probable cause of the Serious Incident was
Who investigated the serious incident involving VT-AIW?
The Aircraft Accident Investigation Bureau (AAIB), India. The final report was signed 285 days after the occurrence, on 22 December 2022. Latest report: final report.
What safety recommendations were made after the serious incident involving VT-AIW?
The report makes 5 safety recommendations. 4.1 Airline should carry out complete monitoring of Flight Data for all parameters defined in the Flight Safety Manual and provide feedback and corrective training to its crew based on trends monitored in FDAP in a timely manner. 4.2 Airline may review its FDM parameters to see the feasibility of including inappropriate flare and delayed retardation of power levers to Flight Idle as a parameter to be monitored in the FDM. 4.3 Airline should re-iterate to its pilots the importance of adherence to stabilized approach criteria.